Forced Ventilation - Frame Size 63 Motor - 230v 1Ph Input
Product Code: 18182
Availability: In stock
Next Working Day Delivery* Please allow an extra working day for Scottish Highlands, Northern Ireland, Channel Islands and Isle of Man (Carriage may be extra for these areas).
Please Note:
To suit our international customers, all prices are displayed ex-VAT. Taxes will be added at Checkout.
Have a question?
Forced Ventilation Unit – Frame 63
Runs from a single-phase 230VAC Supply
Forced ventilation Unit to suit 63 Frame Motors
All Forced Vent. Units are supplied with connector box and instructions for fitting.
IC416 cooling system to suit 63 frame motor 230/1/50 Supply required
Specifications
Length: 121
Inner Diameter: 157
Output: 17
Output Current: 0.12
Speed: 2800
Air Volume: 45
Air Pressure: 40
Noise: 62
When Do I need a Forced Vent Unit?
There is a growing need with variable speed drive applications for motors with improved cooling when operating at low speeds. Closed-loop AC inverters will provide 100% motor torque at zero speed. The simplest way to achieve this is to provide a second, small, constant speed induction motor to drive the cooling fan. The use of force ventilated or separately blown motors is not new, but the advent of static frequency inverters brings new life to the concept. It is essential to use a system of forced ventilation to give the required cooling across the body of the motor. Insufficient cooling will result in: Loss of output power, Nuisance trips, Premature failures.