230v 890CS Common DC Bus Power Supply 7.5kW - 45kW
Select options to suit your application
Please Note: No Options are fitted by the Parker Factory - All are now sold seperately and fitted by the customer
If you would like us to fit them please select the option above
The 890 CS
The AC890CS power supply module is able to provide dual output voltages to power one or more common bus AC890CD, or stand-alone AC890SD drives connected in a common DC bus configuration. This modularity delivers significant space saving in the electrical enclosure.
All 890's will now be shipped as bare Drives, no factory fitted modules or options will be available, you will need to order these and fit in whichever format you require before using your drive.
Features
All 890CS Drives are fitted with a Dynamic Braking Unit and an Operator display for easy diagnostic checking. For increased power, additional units can be connected in parallel. For further details, please call us.
Specification
Technical Specifications - 230v 890CS Common DC Bus Power Supply 7.5kW - 45kW
Electrical Characteristics
Operating Temperature
0 ºC to +45 ºC
Storage Temperature
-25 ºC to +55 ºC
Enclosure Rating
IP20 - UL (c-UL) Open Type (North America/Canada) Type 1
Suitable for cubicle mount only
Cubicle Installation
The 890 must be installed to EN60204 Standard in the cubicle. For USA, the cubicle shall meet the requirements of UL50.
Humidity
Maximum 85% relative humidity at 40 Degrees C non-condensing
Vibration
The product has been tested to the following specification:
Test Fc of EN60068-2-6
10 Hz<=f<=57 Hz sinusoidal 0.075 mm amplitude
57 Hz<=f<=150 Hz sinusoidal 1 g
10 sweep cycles per axis on each of three mutually perpendicular axis